High Frequency Pure Sine Wave Industrial Telecom DC/AC Inverter Single Output 1000W 2U 19-Inch 110V to 220V Converter Peak Power

Product Description

High Frequency Pure Sine Wave Industrial Telecom DC/AC Inverter Single Output 1000W 2U 19-Inch 110V to 220V Converter Peak Power Telecom Inverter Series Banner
Product Overview

EVS series 110v to 220v Converter are designed for the actual needs of communication systems and post and telecommunications. The installation size is small, and the 2U standard 19-inch rack-mounted design can meet the needs of automation and networking of inverter management in the IT era. And low noise has little impact on office or computer room staff.

EVS 110v to 220v Converter adopts advanced SPWM and CPU control technology, with precise control, isolation of input and output, safety, high efficiency, and good reliability, especially for the impact of inductive loads. This series of products are not only small in size, light in weight, beautiful in appearance, easy to install and maintain, simple to operate, low noise, low back-injection noise, and no pollution, but also have real-time data collection and remote communication functions to implement network management and remote monitoring, providing convenience for the majority of system users.

DC125V Series Specifications
rated power 1KW 2KW 3KW 4KW 5KW 6KW 8KW 10KW 12KW
Rated DC voltage DC108V
Battery voltage range DC90-144V Low voltage warning 99V
Low voltage power outage 99V(90-108V(ADJ)
Low voltage recovery 121.5V
High voltage power outage 141V(137-144V ADJ)
High voltage recovery 139.5V
Low voltage shutdown 85.5Vdc
DC priority type Low voltage switching of battery to mains voltage point 99V(94.5-114.5V)
Return to the battery supply voltage point after sufficient supply 117V(108-130.5V)
Input / Output & Environmental Parameters
Communication input Rated AC input voltage AC220V AC110V
Scope of communication input 170-280Vac(UPS) / 90-280Vac(APL) -
Voltage drop point due to under voltage of the municipal power supply 170Vac±5V (UPS) / 90Vac±5V (APL) -
Under voltage recovery point of municipal power supply 180Vac±5V (UPS) / 100Vac±5V (APL) -
Overvoltage and power failure voltage point of mains power 280Vac±5V -
Overvoltage recovery voltage point of mains power 270Vac±5V -
Communication input frequency 50HZ/60HZ(ADJ)
Frequency range 40-65HZ
Single mains power on function yes
UPS conversion time <5ms(UPS);<13ms(Electrical mode)
AC output AC output voltage 220/230/240Vac±3% ADJ -
Communication output frequency 50±1HZ/60±1HZ
Output waveform Pure sine wave (full voltage range)
Waveform distortion rate ≤3%(Linear Load)
Inverter peak efficiency 95%
Dynamic response (0~100%)≤5%
Power factor >0.9
Peak power (surge capability) Twice the rated power in 3 seconds
Idle power consumption (standby power consumption) 30W
power derating No derating (output power will not decrease with the decrease of battery voltage)
work environment Noise (1 meter) ≤40dB
Environmental temperature for use -40℃~+50℃
Storage environment temperature -40℃~+70℃
humidity 0~90%
Using altitude (m) ≤ 5000 (If it is higher than 1000, the usage will be reduced by 10% per liter starting from 1000)
Continuous running time Can run continuously for a long time
Cooling method Temperature controlled variable speed fan for heat dissipation
Mean time between failures Not less than 100000 hours
Inverter Design Banner
Telecom Inverter Front View
Telecom Inverter Structure Details
Telecom Inverter Inside View
Telecom Inverter Internal Design
Telecom Inverter Components
Hot Sale
Hot Sale Inverter Model
Telecom Inverter Operational Guide
Telecom Inverter Wiring Schema
Telecom Inverter Technical Drawing
Telecom Inverter Parameters
Telecom Inverter Display Screen
Telecom Inverter Configuration
Frequently Asked Questions
1. What is the primary function of this 110V to 220V Converter?
It is specifically designed for the automation and networking requirements of communication and post/telecommunications systems, converting stable DC voltage to reliable pure sine wave AC output.
2. How does the 2U rack-mounted design benefit server installations?
The 2U standard 19-inch rack-mounted dimensions allow it to seamlessly slide into IT rack enclosures. This compact design saves valuable server room space and ensures standard compatibility with existing network hardware.
3. Does this system support remote monitoring?
Yes. The inverter is equipped with real-time data collection and remote communication functionalities, making it easy for system operators to implement centralized network management and remote status monitoring.
4. Can this pure sine wave inverter support inductive loads?
Absolutely. The advanced SPWM and CPU control technologies offer robust control, complete electrical isolation between input and output, and excellent safety features. This ensures reliability even under heavy inductive load impacts.
5. What protection measures are built-in for battery low/high voltage?
The device features precise thresholds for low voltage warning, low voltage power shutdown (adjustable between 90-108V), high voltage power outage protection (adjustable between 137-144V), and corresponding recovery voltage configurations.
6. Is the operation noise low enough for normal office environments?
Yes. The system utilizes temperature-controlled variable speed fans for heat dissipation, maintaining a low noise level of ≤40dB at a 1-meter distance, which minimizes the disturbance in office settings or computer rooms.

Related Products